Product features
- Pre-wired cable 7-pole
- Comfortable diagnostics through sensor LED and electronic signalling output
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Misaligned actuation possible
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- Early warning when operating near the limit of the sensor's hysteris range
- Self-monitoring series-wiring of 16 sensors
- 2 short-circuit proof PNP safety outputs
General data
- Standards: EN IEC 60947-5-3, EN IEC 61508
- Working principle: inductive
- Housing construction form: Cylinder, thread
- Installation conditions (mechanical): not flush
- Sensor topology: Sensor for series wiring
- : Individual sensor or end sensor in a series
- Housing material: Glass-fibre, reinforced thermoplastic
- Active area: Glass-fibre, reinforced thermoplastic
- Material of the nuts: Glass-fibre, reinforced thermoplastic
- Reaction time, maximum: 30 ms
- Duration of risk, maximum: 30 ms
- Gross weight: 149 g
General data - Features
- Short circuit detection: Yes
- Cross-circuit detection: Yes
- Safety functions: Yes
- Integral system diagnostics, status: Yes
- Number of semi-conductor outputs with signaling function: 1
- Number of fail-safe digital outputs: 2
- Number of series-wiring of sensors: 16
Safety classification
- Standards: EN ISO 13849-1, EN IEC 60947-5-3, EN IEC 61508
- Performance Level, up to: e
- Category: 4
- PFH value: 2.50 x 10⁻⁹ /h
- Safety Integrity Level (SIL), suitable for applications in: 3
- Mission time: 20 Year(s)